Why do I need to use “CN=Jane” in createobject messages and not just “Jane”?

A quirk of Active Directory is that Organizational Units use an OU property rather than a CN property to define their place in the directory structure. In createobject messages you need to use CN= to create most objects. However, to allow you to create OUs we had to allow you to specify this with OU=MyNewOU.

FAQs
Can we purchase components of the ActiveADAPTER BizTalk Accelerator separately?

Yes. Prices for individual components are included on our price list. Email salesinfo@activeadapter.com for more information.

See the entire answer

My Solicit-Response Send Port Query Is Only Returning 1000 Results

Try adding the setting PageSize="1000" to your query parameters. For example:

<ActiveDirectoryQuery><Directives WhereToBind="LDAP://CN=Users, DC=test, DC=com" Filter="(objectCategory=user)" SearchScope="onelevel" PropertiesToReturn="cn" PageSize="1000"/></ActiveDirectoryQuery>

By default Active Directory only allows for a single page of 1000 results. By explicitly setting this value multiple pages (and hence all results) are returned.

See the entire answer

Can the Active Directory Receive Adapter help me build an orchestration that listens for changes to Active Directory?

Yes. The ON CHANGE ONLY option on the Active Directory Receive Adapter provides this feature. A message is submitted to your BizTalk application only when the results of the query you have specified change. This feature provides a great way to trigger orchestrations and keep information in your Enterprise Applications synchronized.

There is also a REAL-TIME mode that gets events from Active Directory asynchronously and submits them to BizTalk  as they happen.