A REAL-TIME mode listener receive location shuts down reporting: “An operation error occurred.”

This error is often due to security permissions problems. Check if the receive location works fine when pointing to a different container (e.g. the Users container LDAP://CN=Users,DC=test,DC=com). If so:

  • Compare the security permissions on objects created in the working and non-working container
  • Try different accounts in the Authentication tab of the receive location configuration/add the current account to the domain or enterprise admin groups
FAQs
My Solicit-Response Send Port Query Is Only Returning 1000 Results

Try adding the setting PageSize="1000" to your query parameters. For example:

<ActiveDirectoryQuery><Directives WhereToBind="LDAP://CN=Users, DC=test, DC=com" Filter="(objectCategory=user)" SearchScope="onelevel" PropertiesToReturn="cn" PageSize="1000"/></ActiveDirectoryQuery>

By default Active Directory only allows for a single page of 1000 results. By explicitly setting this value multiple pages (and hence all results) are returned.

See the entire answer

Can I use the ActiveADAPTER Send Adapter with dynamic send ports?

Yes. The Send Adapter is fully compatible with dynamic ports.

A sample orchestration showing the use of ActiveADAPTER with dynamic send ports is included in the ActiveADAPTER\Samples folder.

See the entire answer

Is the ability to create Solicit-Response ports that query Active Directory on demand part of the Receive Adapter or the Send Adapter?

Both. The query is sent out by the send adapter. The actual querying is done by components of the receive adapter. Therefore, to be licensed to create Solicit-Response send ports, you need to be licensed for both the ActiveADAPTER send and receive adapters.

See the entire answer